How to reset pentair intellichlor

The optical reader operates with Windows XP and 2000 using Tera Term software; a terminal program included with the IntelliChlor optical reader kit. IntelliChlor Optical Reader User’s Guide. 3. While holding the optical reader over the LED, press and hold the MORE button for 3 seconds until the “percentage” LED's flash quickly.

How to reset pentair intellichlor. The IntelliChlor IC40 model produces 0.45 kg of free available chlorine per day. The IC20 model produces 0.22 kg (0.70 lbs) per day. Salt level bar graph shows the amount of salt in pool. Red and green LED indicators show system status for power, water flow, and cell status.

Pentair EZTouch /. How to disable and enable the chlorinator. How to increase and decrease chlorine out put. How to check diagnostics for issues with chlor...

IntelliChem monitors real-time values of pH, ORP, calculated parts per million (cPPM), and temperature. Continuous monitoring with a sophisticated chemical algorithm means efficient pH and chlorine/bromine control, which helps support chemical effectiveness. Auto Setup/Configuration wizard makes start-up quick and easy.IntelliChlor Power Center Installation Guide Introduction Power Center Overview The IntelliChlor™ system comprises of a Power Center and electrolytic Cell. The Power Center converts AC electrical current to a low voltage DC current required by the IntelliChlor electrolytic cell to operate and create chlorine for the swimming pool and spa.Install the Filter Ring. With the beveled edge facing towards the flow sensor switch, carefully insert and seat the Filter Ring inside the cell opening. Mount the IntelliChlor (SCG) cell onto the couplings. Be sure each O-ring is seated properly. Reconnect the IntelliChlor (SCG) power cable to the IntelliChlor (SCG) Power Center power cable.Plumb the IntelliChlor cell AFTER the filter and heater. If installed on a pool/spa combination system, the plumb the IntelliChlor cell BEFORE the pool/spa return valve to allow proper chlorination of both the pool and spa. See diagram below. View and Download Pentair IC20 instruction manual online.GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defec - tive. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this pump.A common issue with the Pentair Superflow VS variable speed pump is the Ext Control Light to on when this happens you can't run the pump. In this video I sho...We would like to show you a description here but the site won’t allow us.

In this video, We going to wire Pentair IntelliConnect smart pool monitoring system 220 V 2 pump setup. DIY Pentair IntelliConnect - https://amzn.to/3aWKVdG...Low temperature: If the water is too cold, below 70 ° -65 ° F (21 ° -18 ° C), your chlorinator will not be able to produce chlorine even if your salt level is perfect. Salt Chlorinator Flashing High or Low Salt: Make sure to test your salt levels and adjust it to around 3400ppm. if the salt level is off, the salt chlorinator will not work.Pentair Intellichlor IC-40. Sep 18, 2022. #9. Jimrahbe said: Cloey, I just want to confirm that the blinking green light is labeled as the "Cell" light. It will blink if you cell has scale build up inside. If the cell is clean inside, then that means the cell is bad. If this is a new cell it will be covered under warranty.Remove any debris clogging the strainer basket and clean the pool filter if the flow light is red. Replace the AC fuse located at the bottom of the power center if the green power light is not on. Add cyanuric acid to the water of an outdoor pool if the chlorine level is lower than it should be. Aim for 50 to 80 parts per million (ppm), as per ...I would like to understand this for my own information and understanding the impact of the schedule. Answer: 0% - No LEDs lit - No chlorine produced - IntelliChlor Electronic Chlorine Generator is off. 20% - 1 LED lit - Produces chlorine 20% of each hour of pump run time, 12 minutes on, 48 minutes off. 40% - 2 LEDs lit - Produces chlorine 40% ...

To reset your Pentair salt generator, follow these steps:• Unplug the power cord from the unit and wait 5 minutes. • Plug the power cord back in to a grounded outlet. • Hold down both buttons on top of the control panel for 10 seconds until all LED lights turn off. • Release both buttons and allow time for the system to restart (it may ...Last-minute salt runs – and living with hard water – are now a thing of the past with the Connected Salt Level Sensor. Installation is easy with the universal brine tank clip, and setup is simple with step-by-step instructions in the Pentair Home app. But, if you hit a snag, we’re here for you. Anytime. Anywhere.IntelliChem monitors real-time values of pH, ORP, calculated parts per million (cPPM), and temperature. Continuous monitoring with a sophisticated chemical algorithm means efficient pH and chlorine/bromine control, which helps support chemical effectiveness. Auto Setup/Configuration wizard makes start-up quick and easy.Read and keep this Installation and User's Guide in a safe place. Increase Sanitizer Output level as necessary after heavy rain (outdoor pools) and return to normal afterwards. Increase Sanitizer Output level when air and water temperature rise. Increase Sanitizer Output level when number of pool users increase.The percent lights on the IC40 unit (20, 40, 60, 80 and 100) were operating last night - but they didn't blink when the output setting on the EasyTouch differed from these numbers, e.g. when set at 15% on the EasyTouch the 20% light on the IC40 normally blinks, same for 30% on ET and the 40% light on the IC40, etc.As such, that device can only produce .70-poundss of chlorine every 24-hours. The Pentair 520555 is, by contrast once again, meant for pools with a volume of 40,000-gallons. Since this is a higher volume than the 520554, the total output is 1.4-pounds of chlorine every 24-hours. In the end, if the other devices in this guide sound great, but ...

Brookshire's portal login.

The intellichlor Salt Cell has a lifetime of approx 10,000 hours. To check this, press and hold the more button for 3 seconds. The lights should scroll through and leave a few of the percentage lights lit up. The amount of lights corresponds to the amount of life used. If the first three lights are lit (20, 40, and 60%) then you’ve used 6,000 ...Step by step walkthrough of programming a Pentair Intelliflo Variable Speed - Variable Flow PumpThis beautiful salt generator is one of finest chlorinators on the market today. The Pentair IntelliChlor IC20 is approved by the National Sanitation Foundation and features push button operation and full diagnostic capabilities including cell life tracking, salt levels, and water temperatures. Appropriately, the cell unit has water proof ...Sep 8, 2020 · Installation video showing the the steps to replace the flow switch for any Pentair Intellichlor salt cell. Made to showcase the Optimum Pool Technologies r...Installation video showing the the steps to replace the flow switch for any Pentair Intellichlor salt cell. Made to showcase the Optimum Pool Technologies r...

Control From Across the Deck or Around the Globe. The ScreenLogic2 Interface allows you to control the key functions of a pool or spa using the IntelliTouch® and EasyTouch® control systems. You can remotely manage, monitor and control via mobile device. Easily change, track and monitor history of pH and ORP levels when using the IntelliChem ...From https://www.justanswer.com/ythiJustAnswer Customer: I have a Pentair Intellichlor 1C40 Power Center and a Pentair 1C40 Intellichlor Chlorine Generator.J...Set stabilizer to between 30-50 ppm. Ensure no phosphates or nitrates are in the pool water. These chemicals will consume chlorine as fast as it is produced, causing a low-chlorine condition in the water. Set salt level in pool between 3200 and 3400 ppm. Install the IntelliChlor SCG according to the water flow arrow, displayed on the top of the ...INTELLICHLOR Flow-Temperature Switch Replacement Kit Installation Guide 8. Wrap the excess wire around the flow switch. 9. Replace the flow switch cover. 10. The IntelliChlor ® Salt Chlorine Generator is now ready for operation. 11. Switch the power on to the pool pump and the IntelliChlor Salt Chlorine Generator cell. 4intellichlor® salt chlorine generator model ic15 installation and user’s guide registration no. 30931 pest control products act domestic pentair water pool and spa, inc. 10951 west los angeles ave., moorpark, ca 93021 usa. (800) 831-7133 (800) 553-5000 important safety instructions read and follow all instructions save these instructionsResetting your IntelliChlor chlorine generator is a simple process. All you need to do is turn the unit off and unplug it from the power source. Wait five minutes before plugging the unit back in, then turn it back on with the power switch. The IntelliChlor chlorine generator may require additional steps to reset depending on the make and model ...In this video I walk you through the process of replacing the flow switch for the Pentair iChlor salt system. If the "cell" light flickers red, then that mea...Plug the screw terminal onto the four pins located on the Power Center board. Reinstall the cover and secure with the cover screw. Proceed to “Connecting IntelliChlor to an IntelliTouch System,” on page 20 or “Connecting IntelliChlor to an EasyTouch System,” on page 21. Screw terminal. G N D.All Pentair trademarks and logos are owned by Pentair or one of its global affiliates. Pentair Aquatic Systems ®, IntelliChlor ®, EasyTouch , IntelliTouch ®, SunTouch®, Ra inbow™ and Eco S elect ® are trademarks and/ or re gistered trade marks of Pentair Wa ter Po ol and Spa, Inc. and/or its affil iated companiesThe symptoms of hyperthermia include drowsiness, lethargy, dizziness, fainting, and an increase in the internal temperature of the body. The effects of hyperthermia include: 1) Unawareness of impending danger. 2) Failure to perceive heat. 3) Failure to recognize the need to leave the spa.7. Seneca/SC. May 30, 2017. #1. I'm having an issue with a Pentair IC40. It is a newer version with 4000 hours on it according to it. I was checking it yesterday and found all of the lights out and the fuse blown. I replaced the fuse with another 10 amp fast acting 250v fuse and it promptly blew it. I had the sanitizer output set to 60%.

1 Common Issues With Pentair Intellichlor. 1.1 No Power Supply. 1.2 Low Chlorine Production. 2 Troubleshooting Steps. 2.1 Check Power Supply Connection. 2.2 Inspect Cell For Build-up. 3 Preventive Maintenance. 3.1 Regular Cleaning And Inspection. 3.2 Monitoring Chlorine Levels.

The Pentair SuperFlo VS Variable Speed pump is very easy to program and set up. Pentair has gone to great lengths to make this pump as user friendly as possi...If mounting the power pack, mount to a vertical surface within 15 ft. (4.6 m) of the iChlor cell. Align the cell cable connector with the power pack Cell Connection and insert the cell cable. Firmly fasten the cell cable to the power pack. Plug the power pack into the appropriate outlet.The Pentair iChlor 30 salt chlorine generator, part of the swimming pool equipment, was acting up; lights flashing all the time demanding salt, more salt! S...IntelliChlor Salt Chlorinator uses common table salt to produce all the chlorine a pool needs, safely, effectively, and automatically. Same sanitation performance as manual chlorine addition without the drawbacks. No need for customers to buy, transport and store chlorine compounds. Electrolytic chlorine generation (or salt chlorine generation ...Set stabilizer to between 30-50 ppm. Ensure no phosphates or nitrates are in the pool water. These chemicals will consume chlorine as fast as it is produced, causing a low-chlorine condition in the water. Set salt level in pool between 3200 and 3400 ppm. Install the IntelliChlor SCG according to the water flow arrow, displayed on the top of the ...Item No. 387250 | Manufacturer SKU: EC-520888. 2 Reviews. $999.00. Installation Available! Call 1-800-537-5437 for details! Buy in monthly payments with Affirm on orders over $50. Learn more. Pentair IntelliChlor IC15 Salt Cell with 15 Foot Cable and External Power Supply sanitizes smaller pools up to 15,000 gallons. More Details.®Control System Power Center. To reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size toPentair Pool Quick Link for Parts/Equipment: https://amzn.to/3q6MXmf Here the Pool Girl talks about the Pentair salt cells and what light means what!Ask your...Install the acid cleaning kit on the IntelliChlor unit as described on the previous page. 3. Mix one quart of muriatic acid with one gallon of tap water in a plastic five (5) gallon bucket. Always add acid to the water, never add water to the acid. Always wear eye protection and use rubber gloves.To change the Day/ Night Theme: From the Home screen, tap Settings > General > Day/ Night Themes. Select Day Theme, Night Theme or Transition Type (Manual or Auto). Tap Up/Down Arrows: To view multiple screens, tap the UP/Down arrows located on the right side of the screen to move vertically to the next screen or return to the previous screen.

Callaway funeral home marlow ok.

Pnc bank cd.

PentairHow do I connect a Intellichlor salt water chlorinator to a Pentair variable speed pool pump? The timer for the pump is installed on the pump. The company that wired up the pump did not know how to wire the Intellichlor salt generator to the timer on the pump and I am stuck with no way to allow the salt generator to turn on when the pump turns ...Product Features. Power Center required for IC20, IC40, IC60. Can be wired for 220V or 110V. Connects with pool circulation pumpConverts AC electrical current to low voltage DC. Provides communication to and from the IntelliChlor cell. Direct replacement for Pentair 520556. Measures: 6" L x 7"H x 12" W.How to reset ScreenLogic protocol adapter for your pool system? Read this personal experience and learn from other pool owners on Trouble Free Pool.When I faced this issue at first, I did some serious research and I found out that the cell light of the salt cell usually stops working because of 2 main reasons. Reason 1: The fuse of the generator does not work. Reason 2: When the cells become obsolete and need replacement. I recommend to check out the following short video to understand how ...Or give us a call at 407-834-2200, and we would be happy to take your order by phone. Pentair IntelliChlor Parts. ELECTRONIC CHLORINE GENERATOR MODELS IC20 & IC40. Click to zoom in. Diagram #. Part Title. 1/2. IntelliChlor® IC15 ABG Salt Chlorine Generator. 3.8. Press Up/Down button to change the circuit name. 9. Press Right button to select the next circuit number and physical (3/18 will blink). 10. Repeat Steps 6 - 9 to assign a circuit name to the next physical circuit. 11. Press Menu button 3 times to return to Main screen. Assigning Circuit Functions Booster Cleaner 1.In this video I show you how to clean the Pentair iChlor salt cell along with a few tips and tricks. The process and stand needed for the Intellichlor are id...A Pentair IntelliChlor cell light blinking red indicates an issue with the chlorine generation process. The following possible causes should be checked: * Low Salt Levels - Ensure salt levels are at least 3,000 ppm. * High Amperage - Make sure amperage is not more than 15 amps. * Scale Buildup - Clean if scale buildup is present on the ... ….

Part # EC-521105 Warranty Ecommerce (EC) products: Products purchased from an Authorized Pentair Online Reseller (products beginning with EC-) receive a one (1) year (parts only) warranty from the date of purchase. The exceptions are: IntelliChlor cells and IntelliFlo SVRS pumps which receive a two (2) year warranty. EC products are not eligible for the bundled three (3) year extended warranty.Or give us a call at 407-834-2200, and we would be happy to take your order by phone. Pentair IntelliChlor Parts. ELECTRONIC CHLORINE GENERATOR MODELS IC20 & IC40. Click to zoom in. Diagram #. Part Title. 1/2. IntelliChlor® IC15 ABG Salt Chlorine Generator. 3.View and Download Pentair INTELLICHLOR IC15 installation and user manual online. Salt Chlorine Generator. INTELLICHLOR IC15 portable generator pdf manual download. Also for: Intellichlor ic60, Intellichlor ic20, Intellichlor ic40.Acid cleaning must be performed if the cell cannot be reasonably cleaned using water from a high-pressure garden hose. To acid clean the IntelliChlor electrolytic cell: Remove the IntelliChlor unit from the pool system plumbing as described on the previous page. Install the acid cleaning kit on the IntelliChlor unit as described on the previous ...The IntelliCenter® Pool Control System Is Now a Member of the Pentair Home App Family. The Pentair Home app is our premier app experience for managing pool equipment. Its intuitive design and simple navigation allow you to monitor and control your pool from anywhere. IntelliCenter owners can now control their automation system on the Pentair ...The Pentair Intellichlor (SCG) automatically sanitizes your in-ground pool by converting the low concentration level of salt in your pool into free chlorine through electrolysis. This video shows you how to install a Pentair Intellichlor Salt Chlorine Generator (SCG). Note: This video is intended to give you a visual reference to supplement the ...A short to the point video explaining the functions of the Pentair Intellichlor system. This is the newest generation as of this date, some older units may ...Learn how to reset your ScreenLogic2 password in this helpful thread from Trouble Free Pool, a community of pool owners and experts.All Pentair trademarks and logos are owned by Pentair or one of its global affiliates. Pentair Aquatic Systems ®, IntelliChlor ®, EasyTouch , IntelliTouch ®, SunTouch®, Ra inbow™ and Eco S elect ® are trademarks and/ or re gistered trade marks of Pentair Wa ter Po ol and Spa, Inc. and/or its affil iated companiesStep 2. Manually test the salt level with salt test strips or an electronic salt tester. If the salt level is in the proper range of 3000-4200, proceed to step 3. If not, adjust the salt level to the proper parameters before recalibrating. Click here to view test kits. How to reset pentair intellichlor, We would like to show you a description here but the site won’t allow us., The Pentair IntelliChlor chlorine generator is engineered to stand up to the toughest pool conditions and provide years of dependable performance. Titanium electrode cell blades are coated with Ruthenium oxide and are rated for more than 10,000 hours of operation - five years of reliable chlorine output under normal operating conditions., Loosen the flow-temperature switch cable that is wrapped around the switch nut. Note the direction of the arrows on top of the switch nut. Cut the cable close to the switch to allow enough wire for the new switch cable to be connected to. See Figure 2. Using a 1-3/16" (30 mm) adjustable., 3. Switch on the pump and visually inspect for leaks around the couplings. Connecting the IC20, IC40 IC60 Cell Power Cable to the Power Center After the cell installation is completed, connect the power cable to the Power Center: WARNING - Switch OFF main system power to the Power Center before making any connections., 1 Year. BioShield® UV System (Lamp and Quarts Sleeve only) manufactured after October 1, 2023. Ninety (90) days. IntelliChlor® Salt Chlorine Generator (without Power Center) 2 Years. iChlor™ Salt Chlorine Generator - Bundle with Power Supply and Cell (iChlor 15 and iChlor 30) manufactured before October 1, 2023., In this video I detail how to replace an existing Saltwater Chlorinator/Generator (SWG). This is a Pentair Intellichlor IC20 but similar to the IC15, IC30, I..., A common issue with the Pentair Superflow VS variable speed pump is the Ext Control Light to on when this happens you can't run the pump. In this video I sho..., Secure the transformer with three #8-32 x 3/8” screws. Install the GREEN transformer ground lead screw and remaining screw. Connect the red transformer wire (1/4” quick-disconnect) onto the rear of the 12 A circuit breaker. Connect the other RED transformer wire (3/16” quick-disconnect) onto the circuit board terminal., Even if you have an IntelliChlor SCG reset button bracket that the manual says cannot be done. IntelliCenter App Support. The IntelliCenter apps have changed as Pentair improved their software. Prior to firmware 1.064 the app was Intellicenter. With firmware 1.064 and beyond the Intellicenter2 apps and web site was used., Pentair IC40 IntelliChlor® Salt Chlorinator uses common table salt to produce all the chlorine a pool needs, safely, effectively, and automatically. Same sanitation performance as manual chlorine addition without the drawbacks. No need for customers to buy, transport and store chlorine compounds. Electrolytic chlorine generation (or salt ..., All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered logos are the property of their respective owners. ... IntelliChlor® Salt Chlorine Generator) It also includes 32 feature circuits. These can control additional speeds on a variable speed pump or a valve actuator to assign without using ..., How To Program Pentair Pool Pump To Run Continuously. Pumps cannot technically run 24/7 because the pump needs at least a minute to reset—so they can run for 23 hours and 59 minutes. It is pretty close to 24 hours, and you will still get an all-day cleaning. It is recommended to put the schedule on either speed between 5-8 so speeds …, IntelliChem monitors real-time values of pH, ORP, calculated parts per million (cPPM), and temperature. Continuous monitoring with a sophisticated chemical algorithm means efficient pH and chlorine/bromine control, which helps support chemical effectiveness. Auto Setup/Configuration wizard makes start-up quick and easy., Jan 26, 2021 · Position each Power Center keyslot (top and lower) slot over the two mounting screws just installed. Tighten the two screws to secure the enclosure. Install and tighten four mounting screws (two in the top and two in the lower bracket). Bracket screw hole. Cover screw hole., What To Do. Check the installation setup of the controller with the pool lights. Make sure the line voltage input (Black and White) to your Intellibrite controller and switched output wire (Red) is at 120 VAC. If the configuration is correct but the lights still do not respond, there can be several other issues., 1 Year. BioShield® UV System (Lamp and Quarts Sleeve only) manufactured after October 1, 2023. Ninety (90) days. IntelliChlor® Salt Chlorine Generator (without Power Center) 2 Years. iChlor™ Salt Chlorine Generator - Bundle with Power Supply and Cell (iChlor 15 and iChlor 30) manufactured before October 1, 2023., The IntelliConnect® Control and Monitoring system allows pool owners like you to monitor and control your pool equipment from the user-friendly Pentair Home app, from your backyard oasis or anywhere in the world. Controls up to five pool products like pool pumps, filtration, lights and sanitization via WiFi connection., From the rear of the circuit breaker, using needle nose pliers, press the side tabs and slide the circuit breaker out of the front of the bracket. Remove the circuit breakers from the bracket. Install the IntelliCenter Control System 5AMP (P/N 522339) and 4 AMP (P/N 522338) circuit breakers: See Figure 5 on page 7. 4., This video explains what to expect from an intellichem and the recommended settings. If you have any questions feel free to contact us through our website at..., Salt Water Chlorine Generator Test Strips (40 count) $39.49. AQUASALT Aquasalt-40 Swimming Pool and Spa Chlorine Generator Salt-40 lbs. Pound, White. $24.98. Pentair IC40 Salt Cell Chlorine Generator EC-520555. Visit the Pentair Store. 4.5 2,203 ratings. 2K+ bought in past month. $1,14900., The Pentair IntelliChlor can safely, effectively, and automatically use common table salt that you would normally eat food with, to produce all the chlorine a pool would need. ... Paid Expedited Shipping will be shipped at the speed requested but Carriers are subject to change without notice. **** Handling time varies with inventory and ..., Intellichlor Ic40 Reset Button. The Intellichlor IC40 Reset Button is a great feature for quickly resetting the pool chlorine generator without having to turn it off and then on again. The Reset Button can be found at the back of the unit and when pressed, will restart the system's cycle from where it left off before being stopped., Replacement kit contents: † Flow-Temperature switch assembly † Two pair-at-a-time splicer. Step 1: Switch OFF power to the pool pump and the IntelliChlor Salt Chlorine Generator cell before starting. Step 2: Remove the flow-temperature switch from the IntelliChlor Salt Chlorine Generator cell. Cut wire Unscrew nut counterclockwise to remove ..., The Pentair 521171 External Power Supply is for use with Pentair IC15 IntelliChlor Salt Chlorine Generators only. Free Shipping for Pool Perks members ... the purchase of select items, or previous orders. Prices are subject to change without notice. *OFFER VALID ONLINE AND INSTORE. Limits and restrictions apply. Inventory and selection varies ..., 11. Electrical Specifications. 11. 230 VAC Basic System Wiring. 12. Intelllichlor Power Center with ORP Controller. 14. Pentair IntelliChlor IC40 Pdf User Manuals. View online or download Pentair IntelliChlor IC40 Installation And User Manual., The iChlor Salt Chlorine Generator features smart technology that provides built-in intelligence for convenience and control. Just add salt to generate the chlorine your pool needs. iChlor produces a steady stream of pure chlorine for softer, silkier pool water. It's an easy and effective way to maintain a cleaner and more enjoyable pool., 5. Match each of the wire colors and twist the wire together. Place a wire cap on each of the wires. Wrap the excess wire around the flow switch nut. 6. Replace the switch cover and secure it with the small Phillips screw. 7. The IntelliChlor is now ready for operation. 8., Allow the salt to mix for 24 hours before using the IntelliChlor system. 2. Locate a clear spot on a wall, within 15 feet of the IntelliChlor manifold. 3. Locate a clear spot on the return line where the IntelliChlor manifold will be mounted. Be sure that the user can readily see the lights and press buttons if needed. 4., At the bottom of J20 is lists the colors.. So red in the ET to Red in the SWCG power supply box, Yel to Yel, Grn to Grn and Blk to Blk.. You can try just it using just the data lines Yel and Grn, and see if it works, but the manual says to connect all four. Jim R., Nov 27, 2018 ... Pentair IntelliChlor Chlorine Generator Series - http://bit.ly/2NVlEp2 All of Inyo's recommended Salt Chlorine Generators ..., In this video I show you how to clean the Pentair iChlor salt cell along with a few tips and tricks. The process and stand needed for the Intellichlor are id..., The exact method depends on the thermostat, but most programmable thermostats have a reset switch or button. This is often located below the main panel of the thermostat or on the ..., Sep 1, 2016. #2. With no quick Pentair answer arriving, I'll give you the Hayward technique for something easy try. To change Hayward colors you cycle the lights. Turn them off and then back on after 1 second. To sync the lights all to the same color, you turn them on, then off for between 11and 14 seconds, then turn them on again. Report.