Synthes va prox tibia inventory

Our LCP™ Distal Tibia Plates are part of the DePuy Synthes Locking Compression Plate (LCP) System that merges locking screw technology with conventional plating techniques. The stainless-steel plates feature Combi holes, allowing fixation with locking or cortex screws. Product Specifications. How to Use This Product.

Synthes va prox tibia inventory. synthes.vo.llnwd.net

4.5 mm LCP ® Medial Proximal Tibia Plates The DePuy Synthes 4.5 mm LCP® Medial Proximal Tibia Plate is part of the LCP Periarticular Plating System, which merges locking screw technology with conventional plating techniques. The 4.5 mm LCP Medial Proximal Tibia Plate is available in stainless steel and has a limited-contact shaft profile.

2 Synthes LCP Proximal Tibial Plate 3.5 Technique Guide The LCP Proximal Tibial Plate 3.5 is part of the Small Frag-ment LCP System, which merges locking screw technology …Insert the internal fixator between the anterior tibial muscle and the periosteum. Slide the LISS plate in the distal direction with its distal end in constant contact with the bone. Position the proximal end of the fixator against the lateral condyle. Carefully find the correct posi-tion of the LISS on the condyle.Inventory Control Form TN-ADVANCED™ Tibial Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TN-ADVANCED™ Tibial Nailing System Ø 8 mm, Sterile Right Part # Length (mm) 04.043.005S 255 mm 04.043.010S 270 mm 04.043.015S 285 mm 04.043.020S 300 mm 04.043.025S 315 mm 04.043.030S 330 …3.5 mm. Remove the cortex screw from hole 1 and replace it with a bicortical, self-tapping locking screw. Screw the drill sleeve exactly into the threaded part of the combi-hole and drill the hole with the LCP drill bit 4.3 mm. Determine the screw length and insert the screw as described on page 15.Plates, Distal Tibia T- and L-Plates and Distal Fibula Plates. 2.7 mm VA LOCKING CALCANEAL PLATES The pre-contoured, low-profile plates with variable angle (VA) screw placement are designed to reduce the likelihood of soft tissue irritation along the lateral calcaneal wall, with VA locking screws seated flush in the plate.To Order: (800) 523-0322 To Order: (800) 668-1119. Date: Hospital: Surgeon: Procedure: Implants. Patient Information: J7184-C /09. Inventory Control Form. 3.5 mm LCP Extra-articular Distal Humerus Plates (Stainless Steel and Titanium) Available nonsterile or sterile-packed. Add “S” to product number for sterile product.DESCRIPTION. The Titanium Cannulated Tibial Nail-Ex offers a variety of proximal and distal locking options for tibial fractures, allowing the surgeon to tailor fixation to the fracture pattern. The system has a universal design, allowing use on the left or right tibia. Product Specifications. How to Use This Product.

Inventory Control Form 2.7 mm/3.5 mm LCP Distal Fibula Plate System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. DISTFIBICF001 05/22 2 Length 206.028 28 mm 206.030 30 mm 206.035206.014 35 mmThe DePuy Synthes 3.5mm VA-LCP Proximal Tibia plate and the Zimmer Biomet A.L.P.S Proximal Tibia plates were applied in both their fixed and variable angle configurations, with screws aiming posteromedially for the variable angle configurations. Only plates FDA approved for variable angle locking screws were tested in the variable angle ...VA-LCP Proximale Tibiaplatte 3.5, kleine Biegung, rechts, 6 Löcher, Länge 117 mm, Stahl, steril 1 ST B01T01 5 02.127.221S ... Depuy Synthes GmbH OrthoKit® Rental Service VA-LCP Proximale Tibiaplatten 3.5 (Stahl), Steril Number: TV-SPEC-03729 Version: 4.0 Status: Effective Effective Date: 01 Jul 2022 (EST) ...The Arthrex Proximal Tibia Plating System builds on the Titanium Distal Tibia Plating System with the addition of lateral and posteromedial proximal tibia plating options, plateau-specific instruments, and longer screws. All plates accept 4.0 mm fixed-angle locking, 3.5 mm variable-angle locking, and 3.5 mm cortical screws. A T10 driver can be used for all screw sizes. System Features ...Intended use: The DePuy Synthes VA Locking Patella Plating System is intended to provide internal bone fixation for simple, complex, and comminuted patellar fractures. ... Vestergaard V, Pedersen AB, Tengberg PT, et al. 20-year trends of distal femoral, patellar, and proximal tibial fractures: a Danish nationwide cohort study of 60,823 patients ...The FIBULINK Syndesmosis Repair System provides a repair solution for ankle fractures of the syndesmosis. It is compatible with all DePuy Synthes distal fibula plates and is packaged in sterile, single-use packaging. This system features: Stainless steel or titanium implants. Tibia Screw.2 Synthes LCP Proximal Tibial Plate 3.5 Technique Guide The LCP Proximal Tibial Plate 3.5 is part of the Small Frag-ment LCP System, which merges locking screw technology with conventional plating techniques. The LCP Proximal Tibial Plate 3.5 has a limited-contact profile. The head and neck portions of the plate accept 3.5 mm

6 DePuy Synthes 3.5 mm LCP ® Periarticular Proximal Humerus Plate Surgical Technique 01.122.033. Preparation . Required set . 105.434/ Small Fragment LCP Instrument and Implant 145.434 Set, with self-tapping screws (stainless steel or titanium) Optional sets . 01.122.033 Proximal Humerus Instrument Module Set 105.90 Bone Forceps SetEasy plate insertion Compression of the lateral hinge TomoFix technique allows pretension- ng of the plate using cortex screw and TomoFix Knee Osteotomy System TomoFix Tibial Head Plate medial, proximal wedge high tibial - Increased plate strength preload technique stable bridging small stature versions TomoFix Tibial Head Plate lateral, proximal wedge osteotomies stable fixation - Available ...4 Surgical Technique • LCP Posterior Medial Proximal Tibial Plate 3.5 1 Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of Internal Fixation. 3 rd ed. Berlin, Heidelberg New York: Springer 1991. 2 Buckley RE, Moran CG, Apivatthakakul T. AO Principles of Fracture Management: 3 rd ed. Vol. 1: Principles, Vol. 2: Specific fractures. Thieme; 2017.The axial loads were applied on the PLFs by a specially designed load-applicator. We employed a VA LCP proximal tibia plate system (Depuy Synthes) containing proximal posterior rafting as in the control group. Our observations agreed with the reported investigations [12, 16, 17] that the posterior fixation was the sternest PLF fixing method ...the VA-LCP drill sleeve and key into the cloverleaf design of the VA locking hole (1). Use the funnel-shaped end of the VA-LCP drill sleeve to drill variable angle holes at the desired angle (2). Alternatively, use the freehand VA-LCP drill sleeve and insert it fully into the VA locking hole (3). Drill variable angle holes at the desired angle (4).Synthes 3.5 mm VA-LCP PROX TIBIA PLATE SMALL BEND/4H/87 mm/RIGHT Condition: Used 02.127.210

Celebian free tiktok likes.

3. Attach the foot plate support by inserting the exposed portion of the T-bolt into an available hole in the foot plate and tightening with a nut using the Wrench Ø 8.0/11.0 mm. 4. Repeat the process for the second foot plate support on the alternate side. Double check tightness of all connections.Plates, Distal Tibia T- and L-Plates and Distal Fibula Plates. 2.7 mm VA LOCKING CALCANEAL PLATES The pre-contoured, low-profile plates with variable angle (VA) screw placement are designed to reduce the likelihood of soft tissue irritation along the lateral calcaneal wall, with VA locking screws seated flush in the plate.Synthes VA Ankle Trauma is used for ankle fixation in adults and children (12-21) whose growth plates have united, especially in osteopenic bone. The plates are a component of the DePuy Synthes Variable Angle Locking Compression (VA LCP) System, which combines traditional plating methods with technology for variable angle locking screws. The plates are in stainless steel and have an ...Les plaques de verrouillage pour tarse de 2,4/2,7 mm de Synthes sont destinées à la fixation des fractures, aux ostéotomies, aux cas où il y a une absence de consolidation, aux réimplantations et aux arthrodèses de l'os cuboïde, du tarse et de l'os naviculaire, particulièrement en cas d'ostéopénie.

To order (Canada): 844-243-4321. Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. Titanium Patella Plates. Implants. Inventory Control Form. 2.7 mm VA Locking Patella Plating System. Stainless Steel (316L) Patella Plates 2.7 mm Variable Angle Locking Screws, Non-Sterile, (10-60 mm), Stainless Steel.U.S. stocks traded lower midway through trading, with the Dow Jones dropping around 100 points on Wednesday The Dow traded down 0.32% to 31,687.6... U.S. stocks traded lower midwa...Radiographic Ruler for Tibial Nails, length 450 mm 03.010.021 The required nail length must be determined after reduction of the lower leg fracture. Position the image intensifier as for an AP or lateral x-ray of the proximal tibia (position 1). Using long forceps, hold the Radiographic Ruler parallel to the tibia on the lateral side of the ...The LCP Distal Femur Plate are designed with the following key components: Less Invasive Stabilization System (LISS) insertion guide for percutaneous placement of screws. Threaded holes in the plate head that accept cortex screws to create compression. Compatibility with self-tapping, self-drilling, cortex, and periprosthetic locking screws.When not using screws in a variable angle (VA) manner, the fixation effectiveness for posterolateral fragments was 58.3% for the DePuy Synthes locking compression plates (LCP), 47.9% for the DePuy ...The Small Fragment LCP™ System features: Plates with combination locking and compression holes (Combi holes) Ability to create a fixed-angle construct utilizing familiar AO plating techniques. Screws with conical screwhead and large core diameter. Get in Touch with a Sales Consultant.DePuy Synthes offers a full portfolio of complementary plating systems for clavicle fractures and AC joint injuries. In addition to the VA LCP™ Clavicle Hook Plate 2.7 system described in this surgical technique guide, DePuy Synthes offers the VA LCP Clavicle Plate 2.7 t system and the VA LCP Anterior Clavicle Plates 2.7/3.5.Inventory; Delete Set. Manage Set Trays and Contents Save Changes. UNIVERSAL SMALL FRAGMENT VA-LCP PROX TIBIA SET EVAL Add Tray Kit Trays and Contents Collapse All Expand All. Primary Tray (34 Parts) Add products to tray Move To; Top of the kit; Bottom of the kit ...The 3.5 mm LCP® Medial Proximal Tibia Plate is part of the DePuy Synthes Locking Compression Plate (LCP) System that merges locking screw technology with conventional plating techniques. The 3.5 mm LCP Medial Proximal Tibia Plate is available in stainless steel or titanium and has a limited-contact shaft profile.

The Variable Angle LCP Proximal Tibial Plate 3.5 is part of the VA-LCP Periarticular Plating System, which combines variable angle locking screw technology with c onventional plating techniques. Variable angle (VA) locking technology. Four columns of threads in the VA locking holes provide a fi xed-angle construct at the desired screw angle.

The 2.7mm VA LCP™ Clavicle Hook Plate System provides solutions for lateral clavicle fractures with associated acromioclavicular and coracoclavicular ligament injuries and isolated ligamentous injuries. The Clavicle Hook Plates have enhanced hook depths and angulations based on an extensive analysis of shoulder morphology. 1,2 *.The specific identification method is used for inventories of large items, like equipment, to determine the cost of goods sold. Accounting | What is Download our FREE Guide Your Pr...Remove the drill sleeve, pass the measuring hook through the hole in the plate, and read the screw length from the depth gauge. Alternatively, read the calibration directly after drilling from the drill bit at the back of the drill sleeve. Then remove the drill bit and drill sleeve. Remove the 2.0 mm Kirschner wires.Background: The aim of this study was to evaluate the clinical and/or radiologic outcome using different polyaxial locking plates for the treatment of proximal tibia fractures, the Non-Contact-Briding plate (NCB-PT®) by Zimmer or the Variable Angle Locking Compression Plate (VA-LCP®) by Synthes. Methods: This study enrolled 28 patients with proximal tibia fractures (AO/ OTA 41 B-C) and ...the VA-LCP drill sleeve and key into the cloverleaf design of the VA locking hole (1). Use the funnel-shaped end of the VA-LCP drill sleeve to drill variable angle holes at the desired angle (2). Alternatively, use the freehand VA-LCP drill sleeve and insert it fully into the VA locking hole (3). Drill variable angle holes at the desired angle (4).Complete (LISS) Inventory Control Form online with US Legal Forms. Easily fill out PDF blank, edit, and sign them. ... Inventory Control Form Titanium LCP Distal Femur and LCP Proximal Lateral Tibia (LISS) SYNTHES (USA) To Order: (800) 5230322Patient Information:SYNTHES (Canada) Ltd. To Order: (800) 6681119Date: Hospital: Surgeon: Procedure ...At DePuy Synthes, our mission is to keep people moving through innovations in orthopaedic surgery, support and education for providers, and a dedication to improving diversity, inclusivity, and equality throughout the healthcare system. With new advancements in orthopaedic devices, medical technology, and digital surgery across the continuum of care, we are proud to provide surgeons with ...Inventory Control Form 3.5 mm LCP™ Proximal Tibia Plating Systems Length 204.830 30 mm 204.832 32 mm 204.834 34 mm 204.836 36 mm 204.838 38 mm 204.840 40 mm 204.845 45 mm 204.850 50 mm 204.855 55 mm 204.860 60 mm 4.0 mm Cancellous Screws, fully threaded Length 206.010 10 mm 206.012 12 mm 206.014 14 mm 206.016 16 mm 206.018 18 mmRadiographic Ruler for Tibial Nails, length 450 mm 03.010.021 The required nail length must be determined after reduction of the lower leg fracture. Position the image intensifier as for an AP or lateral x-ray of the proximal tibia (position 1). Using long forceps, hold the Radiographic Ruler parallel to the tibia on the lateral side of the ...

Ashley stern fiance.

How to get dying embers deepwoken.

synthes.vo.llnwd.netProximal Non-displaced fracture : of first metatarsal bone Displaced fracture of : 4th metacarpal bone Hairline middle phalanx fracture: Phalanges ... The DePuy Synthes VA Locking Hand System (Figure 2) features a number of design elements which were developed to deliver clinical and economic value to the hospital, surgeon, and patient. ...The FRN-ADVANCED System is intended for treatment of fractures in adults and adolescents in which the growth plates have fused. Intended applications include: Subtrochanteric fractures. Ipsilateral neck/shaft fractures. Femoral shaft fractures. Impending pathologic fractures. Malunions and nonunions. Get in Touch with a Sales Consultant.DESIGN EVIDENCE TFN-ADVANCED™ Proximal Femoral Nailing System (TFNA) Rotational and Static Locking ABSTRACT The TFN-ADVANCED™ Proximal Femoral Nailing System (TFNA) features a pre-assembled locking mechanism within the nail to allow the intra-operative decision of rotational locking (control the rotation of the helical blade or lag screw) or statically locking (control the rotation and ...Consult Depuy Synthes's entire LCP Distal Femur / Promixal Lateral Tibia 4.5 catalogue on MedicalExpo. Page: 1/12. Exhibit with us {{>currencyLabel}} Back ... Insert the locking screw through the guiding block. 6 Synthes LCP DF and PLT . Open the catalog to page 8. Product Information Note: Long LCP DF plates from 15-19 holes are available in ...3.5 mm VA LCP® Proximal Tibia Plate System Surgical Technique DePuy Synthes 9 PLATE INSERTION AND FIXATION 1 Determine plate type Instruments 03.127.012 3.5 mm VA-LCP Proximal Tibia Trial Implant, Small Bend, Right 03.127.013 3.5 mm VA-LCP Proximal Tibia Trial Implant, Small Bend, Left 03.127.014 3.5 mm VA-LCP Proximal Tibia TrialInventory Control Form. 3.5 mm VA-LCP Proximal Tibia Plate System. Patient Information: Synthes (USA) To Order: (800) 523-0322. Synthes (Canada) Ltd. To Order: (800) 668-1119. Date: Hospital: Surgeon: Procedure: Implants. 3.5 mm VA-LCP Proximal Tibia Plates, Small Bend 3.5 mm VA-LCP Proximal Tibia Plates, Large Bend.Inventory; Delete Set. Manage Set Trays and Contents Save Changes. UNIVERSAL SMALL FRAGMENT VA-LCP PROX TIBIA SET EVAL Add Tray Kit Trays and Contents Collapse All Expand All. Primary Tray (34 Parts) Add products to tray Move To; Top of the kit; Bottom of the kit ...Discover DePuy Synthes portfolio of Trauma & Extremities solutions. Our products offer options for treating fractures and a wide range of deformities. ... Proximal Tibia (24) Foot & Ankle (42) Fibula (17) Distal Tibia (28) Midfoot/Hindfoot (20) Forefoot (13) Product Type. ... 2.7 MM VA LCP™ CLAVICLE System. Variable Angle LCP™ Clavicle Hook ...The LCP™ Wrist Fusion Set's anatomic plate design combines LCP™ System technology distally in the metacarpal and proximally in the radial shaft. This technology allows for angular stable fixation and compression of the fusion site to ensure quality bone contact, even in osteopenic bone. Product Specifications.Important: Determine proximal screw placement and screw lengths to ensure proper screw placement in the metaphysis. Position the patient supine on a radiolucent operating table. Visualization of the proximal tibia under fluoroscopy in both the lateral and AP views is necessary. 6 Synthes 3.5 mm LCP Medial Proximal Tibia Plates ….

Système VA LCP 2.7/3.5 pour la traumatologie de la cheville Plaque VA LCP pour clavicule antérieure Plaque condylienne VA LCP 4.5/5.0 Plaques VA LCP 2.7/3.5 pour humérus distal Plaques VA LCP 2.7/3.5 pour olécrane Plaque VA LCP 3.5 pour tibia proximal Système va locking pour arthrodèse intercarpienneInventory Control Form 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. 2.7 mm / 3.5 mm Variable Angle LCP Medial Distal Tibia Plates 02.118.002 4 holes, right 02.118.003 4 holes, left 02.118.004 6 holes, right 02.118.005 6 holes, leftHow to fill out synforms va proximal tibia: 01. Begin by gathering all the necessary information required to complete the form, such as the patient's name, date of birth, and contact information. 02. Carefully read the instructions provided on the form to ensure you understand each section and the information it requires.How to fill out synforms va proximal tibia: 01. Begin by gathering all the necessary information required to complete the form, such as the patient's name, date of birth, and contact information. 02. Carefully read the instructions provided on the form to ensure you understand each section and the information it requires.DESCRIPTION. Our LCP™ Curved Locking Compression Plates are part of the DePuy Synthes Trauma LCP™ Locking Compression Plate System. This stainless steel and titanium plate screw system merges locking screw technology with conventional plating techniques for use in various orthopaedic trauma applications. Get in Touch with a Sales …LCP Medial Proximal Tibial Plate 3.5 LCP Medial Proximal Tibial Plate 4.5/5.0 LCP Metaphyseal Plate for distal medial tibia LCP Metaphyseal Plates LCP Olecranon Plate LCP Pediatric Condylar Plate 90°, 3.5 and 5.0 LCP Pediatric Plate System LCP Periarticular Proximal Humerus Plate 3.5 LCP Posterior Medial Proximal Tibial Plate 3.5Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU.Sistema de osteosíntesis con premoldeado anatómico y estabilidad angular para diafisarias y laterales de clavícula. Placa VA-LCP 2.7/3.5 para clavícula anterior, lateral (7, 9, 10, 11 y 12 agujeros) Agujeros del cuerpo. Para tornillos de bloqueo de 3.5 mm, tornillos de cortical de 3.5 mm o tornillos de esponjosa de 4.0 mm. Synthes va prox tibia inventory, Use the Torque Limiter 1.5 Nm (511.115) and the Screwdriver Shaft (Hex 314.030, Stardrive 314.116) for the motor-driven insertion of the locking screw. Stop the motor before locking, fix the torque limiter and the screw-driver shaft to the Handle with Quick Coupling (311.431) and tighten the screw. After one click, the optimal torque is reached., Synthes 3.5 mm VA-LCP PROX TIBIA PLATE SMALL BEND/6H/117 mm/LEFT Condition: Used 02.127.221 ... Inventory. Warranty. All For warranty information please visit our FAQ page. Related Products 532.022 Synthes K-Wire Coupling. $50.00 ..., One of the easiest ways you can waste money is by wasting food you've already paid for. Instead of throwing out all the food you forgot about, use a magnetic whiteboard to keep tr..., Inventory Control Form Variable Angle LCP Distal Radius Plates Implants (cont’d) 2.7 mm Cortex Screw, self-tapping, Drill Bits with T8 STARDRIVE Recess Plate Reduction Wires 2.4 mm Locking Screw, self-tapping, with T8 STARDRIVE Recess 1.25 Plate Reduction Wire, threaded top with large stop, 150 mm Kirschner Wires with T8 STARDRIVE Recess 02 ..., Now that summer is over, it's a good time to log into your airline and hotel accounts. Check to see how many points or miles you have, when they expire and check for any leftover c..., Also included in Synthes 3.5 mm Cannulated Screw Instrument and Implant Set (105.03). Includes a range of short thread and long thread 3.5 mm Cannulated Screws. CLICK HERE for a full list of 3.5 mm Cannulated Screws. See close-up of 205.224 and 205.024 below., Instruments. 03.010.110 Cannulated StarDrive Screwdriver, T40 357.399 3.2 mm Guide Wire, 400 mm All titanium end caps for the Tibial Nail-EX are available in extension lengths of 0 mm, 5 mm, 10 mm, and 15 mm. They prevent bone ingrowth into the nail and they extend the nail height if it is overinserted., Keeping track of your possessions and cargo during a move can be difficult. We’re here to help with our comprehensive guide to home inventory lists. Expert Advice On Improving Your..., synthes.vo.llnwd.net, synthes.vo.llnwd.net, A.L.P.S. Distal Tibia Plating System 14 Medial Distal Tibia Locking Plate Compression holes in the shaft of the plate for 3.5 mm and 4.0 mm Non-Locking Screws Distal tab for 3.5 mm and 4.0 mm Non-Locking Screw conforms to shape of medial malleolus Proximal bullet tip facilitates submuscular plate insertion Low-profile, anatomically contoured plate, La placa LCP 4.5 para fémur proximal es una placa de acero inoxidable de contacto limitado. La porción proximal de la placa está premoldeada para adaptarse al fémur proximal. Sus dos agujeros proximales están diseñados para alojar tor-nillos canulados de bloqueo de 7.3 mm; el tercer agujero está diseñado para alojar tornillos canulados ..., Instructions for Use (IFU) Johnson & Johnson Institute. Reimbursement Resources. Investigator Initiated Studies. CA Compliance. ASR Recall. . The Advanced Nailing System is a portfolio of nails to treat various fractures in the tibia and femur as per approved indications., LCP Distal Femur and LCP Proximal Lateral Tibia (LISS) Stainless Steel and Titanium. Synthes (USA) To Order: (800) 523-0322 Synthes (Canada) Ltd. To Order: (800) 668-1119., LOQTEQ® Proximal Lateral Tibia Plate 3.5. Various holes for K-wires and an oblong hole facilitate primary fixation of the plate. An exceptional anatomical fit to the lateral condyle minimizes the need for intra- operative plate con touring. 4 proximal screws slightly diverge for optimum support of the tibial plateau., 02.130.150, 02.130.150S, 02.130.151... View More. PRODUCT CODES. DESCRIPTION. The Variable Angle Locking Hand System consists of 40 different basic and specialty plates, available in stainless steel and titanium, including fragment-specific plates designed for lateral and dorsal application in fracture repair and deformity correction., DePuy Synthes Stainless Steel Right Low Bend LCP Proximal Tibial Plate, 3 ... Surplus Inventory Form; Contact Us; FAQs; Government; Our Company; Our History; Meet Our Team; Join Our Team; Media Page; Blog; Account . DEPUY SYNTHES: 02.124.200. Quantity Available:2. LCP Proximal Tibial Plate, 3.5 mm Size, Stainless Steel, 76 mm Length, 4 Shaft ..., Synthes 3.5mm LCP Posteromedial Proximal Tibia Plates are indicated for internal fixation of posteromedial proximal tibia fractures including buttressing of fractures of the proximal, distal, and metaphyseal areas of the tibia. Prescription Use X AND/OR Over-The-Counter Use (Per 21 CFR 801.109) (21 CFR 807 Subpart C) ..., The LCP™ Wrist Fusion Set's anatomic plate design combines LCP™ System technology distally in the metacarpal and proximally in the radial shaft. This technology allows for angular stable fixation and compression of the fusion site to ensure quality bone contact, even in osteopenic bone. Product Specifications., The DePuy Synthes LCP™ Proximal Femoral Hook Plate 4.5/5.0 is part of the LCP Periarticular Plating System, which merges locking screw technology with conven - ... • LCP Proximal Tibia Plate 4.5/5.0 • LCP Medial Proximal Tibia Plate 4.5/5.0 Locking Compression Plate The Locking Compression Plate (LCP) has combi-holes in, DESCRIPTION. The LCP™ Locking Attachment Plate offers an alternative to cerclage cables and uses a connecting screw to augment the stabilization of fractures. The locking capability stabilizes fixed-angle constructs in periprosthetic fractures, and fractures in the presence of intramedullary implants. Product Specifications., Features and Benefits The Synthes LCP Proximal Femoral Hook Plate 4.5/5.0 is part of the LCP Periarticular Plating System, which merges locking screw technology with conventional plating techniques. LCP Periarticular Plating System The LCP Periarticular Plating System is capable of addressing: – complex fractures of the distal femur with the ..., Inventory Control Form ... 2.4 mm Titanium VA LCP ... Synthes USA Products, LLC 1302 Wrights Lane East West Chester, PA 19380 To order (USA): 800-523-0322 To order (Canada): 855-946-8999 Note: For recognized manufacturer, refer to the product label. www.depuysynthes.com, Universal Small Fragment System. Surgical Technique. 2.7 mm/3.5 mm Non-locking, Locking, and Variable Angle Locking Technology. Image intensifier control This description alone does not provide sufficient background for direct use of DePuy Synthes products. Instruction by a surgeon experienced in handling these products is highly recommended., The Synthes Proximal Femur Plates family of implantable devices consist of LCP™ Proximal Femoral Plate 4.5/5.0 and Synthes LCP™ Proximal Femoral Hook Plate 4.5/5.0 and are available in various sizes ... TomoFix® Medial High Tibia Plate; Variable Angle Locking Calcaneal Plating System (2.7 mm) ... 2.7 MM VA LCP™ CLAVICLE System; …, The Synthes Locking Compression Plates—T-Plates are intended to buttress metaphyseal fractures of the proximal humerus, medialtibial plateau and distal tibia. They are also for use in fixation of osteopenic bone and fixation of nonunions and malunions. The Synthes LCP Proximal Tibia Plate is intended for treatment of non-unions, malunions,, BitTorrent isn’t the quiet haven it once was. These days, everyone’s looking to throttle your connection, spy on what you’re downloading, or even send you an ominous letter. If you..., Page 4 and 5: VA-LCP Proximal Tibial Plate 3.5. P; Page 6 and 7: AO Principles In 1958, the AO formu; Page 8 and 9: Preparation 1 Preparation Required ; Page 10 and 11: Preparation 3 Surgical approach Dep; Page 12 and 13: Plate Insertion and Fixation 2 Prep; Page 14 and 15: Plate Insertion and Fixation Insert, The Variable Angle LCP™ Curved Condylar Plate is a distal femur implant designed to address multiple patient anatomies, fracture patterns and surgical situations including supracondylar, intra-articular and extra-articular condylar fractures, and periprosthetic fractures. Product Specifications. How to Use This Product., How to fill out synforms va proximal tibia: 01. Begin by gathering all the necessary information required to complete the form, such as the patient's name, date of birth, and contact information. 02. Carefully read the instructions provided on the form to ensure you understand each section and the information it requires., SYNTHES USA AIMING ARM FOR 3.5MM VA-LCP PROXIMAL TIBIA PLATE PLATE, FIXATION, BONE: Back to Search Results: Catalog Number 03.127.009: Device Problem Failure to Align (2522) ... It was reported that during a proximal tibial plate insertion on (b)(6) 2015 the surgeon noticed that the aiming arm did not line up with the standard tibial plateau ..., Instrument assembly. 1. Choose the matching guiding block and place it onto the plate head. Make sure that the three-point locking mech-anism is positioned on the pre-contoured reference points of the plate. 2. Insert a first LCP drill sleeve through the guiding block into the central hole (A) of the plate and tighten it., Inventory Control Form 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. 2.7 mm / 3.5 mm Variable Angle LCP Medial Distal Tibia Plates 02.118.002 4 holes, right 02.118.003 4 holes, left 02.118.004 6 holes, right 02.118.005 6 holes, left